%ITER Card

This card can be used to control the iterations in ADPRES calculation

%ITER Variable Description Remarks
LINE 1 NOUT Maximum number of outer iteration Default = 500
  NIN Maximum number of inner iteration per an outer iteration Default = 2
  SERC Fission source error criteria (relative error) Default = 1.e-5
  FERC Flux error criteria (relative error) Default = 1.e-5
  NAC Outer iteration fission source extrapolation interval Default = 5
  NUPD Nodal update interval through outer iteration Default = (NX+NY+NZ)/2.5. Effective only for ANM and PNM nodal kernel
  TH_NITER Maximum number of T-H iteration Default = 30. Effective only if %THER present
  NTH Maximum number of outer iteration per T-H iteration Default = 20. Effective only if %THER present

Note: TH iteration is non-linear iteration to determine TH parameters

Example:

! Iteration control card
%ITER
! Set maximum number of outer iteration = 1200
! Set maximum number of inner iteration = 3
! Set fission source error criteria = 1.e-5
! Set flux error criteria = 1.e-5
! Set fission source extrapolation interval every 25 outer iterations
! Set nodal update interval every 40 outer iterations
! Set maximum number of TH iterations = 20
! Set maximum number outer iterations for each TH iteration is 80
1200 3 1.e-5 1.e-5 25 40 20 80