%THER Card
This card is used to set the T-H parameters. It also activates T-H feedback. When %THER card present, either conditions must be satisfied
%FTEMand one or more of these cards shall also present:%MTEMand%CDEN%XTABshall be present
%THER |
Variable | Description | Remarks |
|---|---|---|---|
| LINE 1 | PPOW | Percent reactor power | 0.0 < PPOW <= 100.0 |
| LINE 2 | POW | Reactor thermal power for given geometry in %GEOM card in Watt |
|
| LINE 3 | TIN | Coolant inlet temperature in Kelvin | |
| CMFLOW | Coolant mass flow rate in kg/s | ||
| LINE 4 | RF | Fuel meat (UO2) radius in meter | |
| TG | Gap thickness in meter | ||
| TC | Cladding thickness in meter | ||
| PPITCH | Fuel pin pitch in meter | ||
| LINE 5 | NFPIN | Number of fuel pin for each assembly | |
| NGT | Number of guide tubes | ||
| LINE 6 | CF | Fraction of heat deposited in the coolant |
Example:
! THERMAL-HYDRAULIC CARD
%THER
100. ! Percent power in %
891.25e6 ! Reactor thermal power for quarter geometry in Watt
560. 82.121243523 ! Inlet coolant temp. (Kelvin) and Fuel Assembly Mass flow rate (kg/s)
3.951E-03 5.9E-05 5.73E-04 1.26E-2 ! Fuel meat rad., gap thinkness, cladding thinkness and pin picth (m)
264 25 ! Number of fuel pin and guide tubes
0.0 ! FRACTION OF HEAT DEPOSITED IN COOLANT
1