Skip to the content.

%ITER Card

This card can be used to control the iterations in KOMODO calculations. You may use this if the default iteration parameters lead to calculation instability.

%ITER Variable Description Remarks
LINE 1 NOUT Maximum number of outer iteration Default = 500. Not used if %THER card active
  NIN Maximum number of inner iteration per an outer iteration Default = 2
  SERC Fission source error criteria (relative error) Default = 1.e-5
  FERC Flux error criteria (relative error) Default = 1.e-5
  NAC Outer iteration fission source extrapolation interval Default = 5
  NUPD Nodal update interval through outer iteration Default = (NX+NY+NZ)/2.5. Effective only for ANM and PNM nodal kernel
  TH_NITER Maximum number of T-H iteration Default = 30. Effective only if %THER is active and if the calculation mode is NOT BCSEARCH
  NTH Maximum number of outer iteration per T-H iteration Default = 20. Effective only if %THER card active

Note: TH iteration is non-linear iteration to determine TH parameters

Example:

! Iteration control card
%ITER
1200 3 1.e-5 1.e-5 25 40 20 80

What we have done here is:

  1. Set maximum number of outer iteration = 1200
  2. Set maximum number of inner iteration = 3
  3. Set fission source error criteria = 1.e-5
  4. Set flux error criteria = 1.e-5
  5. Set fission source extrapolation interval every 25 outer iterations
  6. Set nodal update interval every 40 outer iterations
  7. Set maximum number of TH iterations = 20
  8. Set maximum number outer iterations for each TH iteration is 80